92 lines
3.9 KiB
TypeScript
92 lines
3.9 KiB
TypeScript
// types/siteData.ts
|
|
export type SiteName = 'Site A' | 'Site B' | 'Site C';
|
|
|
|
export interface SiteDetails {
|
|
location: string;
|
|
inverterProvider: string;
|
|
emergencyContact: string;
|
|
lastSyncTimestamp: string;
|
|
consumptionData: number[]; // e.g., Daily consumption in kWh
|
|
generationData: number[]; // e.g., Daily generation in kWh
|
|
|
|
// Properties for SystemOverview
|
|
systemStatus: string; // e.g., "Normal", "Faulty"
|
|
temperature: string; // e.g., "35°C"
|
|
solarPower: number; // Power generated by solar (kW) - Real-time
|
|
realTimePower: number; // Real-time power used (kW)
|
|
installedPower: number; // Installed capacity (kWp)
|
|
|
|
// New properties for KPI calculations (assuming these are base values for the month)
|
|
// If consumptionData/generationData are daily, we will sum them up.
|
|
// If they were monthly totals, you'd name them appropriately.
|
|
// Let's assume these are the *raw data points* for the month.
|
|
// monthlyConsumptionkWh?: number; // Optional, if you want to store a pre-calculated total
|
|
// monthlyGenerationkWh?: number; // Optional, if you want to store a pre-calculated total
|
|
|
|
// For savings calculation:
|
|
gridImportPrice_RM_per_kWh: number; // Price paid for electricity from the grid
|
|
solarExportTariff_RM_per_kWh: number; // Price received for excess solar sent to grid (e.g., FiT)
|
|
theoreticalMaxGeneration_kWh?: number; // For efficiency calculation (e.g., based on installedPower * peak sun hours)
|
|
}
|
|
|
|
// Helper function to sum data for monthly totals (if consumptionData/generationData are daily)
|
|
const calculateMonthlyTotal = (dataArray: number[]): number => {
|
|
return dataArray.reduce((sum, value) => sum + value, 0);
|
|
};
|
|
|
|
const generateYearlyDataInRange = (min: number, max: number) =>
|
|
Array(365)
|
|
.fill(0)
|
|
.map(() => Math.floor(Math.random() * (max - min + 1)) + min);
|
|
|
|
|
|
export const mockSiteData: Record<SiteName, SiteDetails> = {
|
|
'Site A': {
|
|
location: 'Petaling Jaya, Selangor',
|
|
inverterProvider: 'SolarEdge',
|
|
emergencyContact: '+60 12-345 6789',
|
|
lastSyncTimestamp: '2025-06-03 15:30:00',
|
|
consumptionData: generateYearlyDataInRange(80, 250),
|
|
generationData: generateYearlyDataInRange(80, 250),
|
|
systemStatus: 'Normal',
|
|
temperature: '35°C',
|
|
solarPower: 108.4,
|
|
realTimePower: 108.4,
|
|
installedPower: 174.9, // kWp
|
|
gridImportPrice_RM_per_kWh: 0.50, // Example: RM 0.50 per kWh
|
|
solarExportTariff_RM_per_kWh: 0.30, // Example: RM 0.30 per kWh
|
|
theoreticalMaxGeneration_kWh: 80000, // Example: Theoretical max for 174.9 kWp over a month in Malaysia
|
|
},
|
|
'Site B': {
|
|
location: 'Kuala Lumpur, Wilayah Persekutuan',
|
|
inverterProvider: 'Huawei',
|
|
emergencyContact: '+60 19-876 5432',
|
|
lastSyncTimestamp: '2025-06-02 10:15:00',
|
|
consumptionData: generateYearlyDataInRange(200, 450),
|
|
generationData: generateYearlyDataInRange(200, 450),
|
|
systemStatus: 'Normal',
|
|
temperature: '32°C',
|
|
solarPower: 95.2,
|
|
realTimePower: 95.2,
|
|
installedPower: 150.0,
|
|
gridImportPrice_RM_per_kWh: 0.52,
|
|
solarExportTariff_RM_per_kWh: 0.32,
|
|
theoreticalMaxGeneration_kWh: 190000,
|
|
},
|
|
'Site C': {
|
|
location: 'Johor Bahru, Johor',
|
|
inverterProvider: 'Enphase',
|
|
emergencyContact: '+60 13-555 1234',
|
|
lastSyncTimestamp: '2025-06-03 08:00:00',
|
|
consumptionData: generateYearlyDataInRange(400, 550),
|
|
generationData: generateYearlyDataInRange(400, 550),
|
|
systemStatus: 'Faulty',
|
|
temperature: '30°C',
|
|
solarPower: 25.0,
|
|
realTimePower: 70.0,
|
|
installedPower: 120.0,
|
|
gridImportPrice_RM_per_kWh: 0.48,
|
|
solarExportTariff_RM_per_kWh: 0.28,
|
|
theoreticalMaxGeneration_kWh: 180000, // Lower theoretical max due to fault or smaller system
|
|
},
|
|
}; |