array: peak_power_demand: 900 # in kWac DC_AC_ratio: 1.2 # ratio of DC to AC power spacing: 0.4 # spacing between adjacent panel rows in m edge_setback: 1.8 # distance from the edge of the roof to the array roof_slope: 0 slope: 0 # degrees from horizontal (+ve means shaded row is higher than the row in front) horizontal_max_capacity: 0.75 # scale down due to peak power demand limit of NOVA performance_ratio: 0.9 # ratio of actual energy output to the theoretical maximum simulation_date_time: start: 2025-03-30 00:00 # start date and time in ISO 8601 format end: 2025-03-30 23:45 # end date and time in ISO 8601 format tz: Asia/Kuala_Lumpur # timezone for the simulation environment: roof: dimensions: # dimensions all in m length: 50 width: 40 albedo: 0.2 # % of light reflected from the surface tilt: 0 # degrees from horizontal location: latitude: 3.1186108758412945 longitude: 101.57639813680093 panel: peak_power: 710 # in Wp efficiency: 0.229 # max efficiency of the front face bifaciality: 0.85 # rear face efficiency relative to front face # dimensions all in m dimensions: length: 2.384 width: 1.303 thickness: 0.033 temperature_coefficient: -0.0029 # /°C nominal_operating_cell_temperature: 43 # °C