array:
peak_power_demand: 900 # in kWac
DC_AC_ratio: 1.2 # ratio of DC to AC power
spacing: 3 # spacing between adjacent panel rows in m
edge_setback: 1.8 # distance from the edge of the roof to the array
roof_slope: 0
slope: 0 # degrees from horizontal (+ve means shaded row is higher than the row in front)
horizontal_max_capacity: 0.75 # scale down due to peak power demand limit of NOVA
performance_ratio: 0.9 # ratio of actual energy output to the theoretical maximum
simulation_date_time:
start: 2025-03-30 00:00 # start date and time in ISO 8601 format
end: 2025-03-30 23:45 # end date and time in ISO 8601 format
tz: Asia/Kuala_Lumpur # timezone for the simulation
environment:
roof:
dimensions:
# dimensions all in m
length: 100
width: 40
albedo: 0.2 # % of light reflected from the surface
tilt: 0 # degrees from horizontal
height: 50 # elevation including building height
location:
latitude: 3.1186108758412945
longitude: 101.57639813680093
panel:
peak_power: 710 # in Wp
efficiency: 0.229 # max efficiency of the front face
bifaciality: 0.85 # rear face efficiency relative to front face
# dimensions all in m
dimensions:
length: 2.384
width: 1.303
thickness: 0.033
temperature_coefficient: -0.0029 # /°C
nominal_operating_cell_temperature: 43 # °C